P-2507-Feb-2007

NYISO Operational Announcements


Dispatcher Notices
Committed for Reliability
Market Monitor Notices

Dispatcher Notices

Back to top
Insert TimeMessage
07-Feb-2007 00:08:11ISO REQUESTS NIAGARA____ OUT OF MERIT. COMMITED FOR ISO RELIABILITY AT START TIME 02/07/2007 00:00 FOR .
07-Feb-2007 00:28:54ISO REMOVES NIAGARA____ OUT OF MERIT. COMMITED FOR ISO RELIABILITY AT START TIME 02/07/2007 00:00.
07-Feb-2007 04:30:12Metering Authority - Consolidated Edison of NY UPDATES EAST_RIVER___2 OUT OF MERIT. OOM FOR TO LOCAL SECURITY AT START TIME 02/07/2007 04:00 FOR Steam sendout.
07-Feb-2007 04:30:39Metering Authority - Consolidated Edison of NY UPDATES EAST_RIVER___1 OUT OF MERIT. OOM FOR TO LOCAL SECURITY AT START TIME 02/07/2007 04:00 FOR Steam sendout.
07-Feb-2007 04:54:12Metering Authority - Consolidated Edison of NY UPDATES EAST_RIVER___2 OUT OF MERIT. OOM FOR TO LOCAL SECURITY AT START TIME 02/07/2007 04:00 FOR Steam sendout.
07-Feb-2007 04:54:33Metering Authority - Consolidated Edison of NY UPDATES EAST_RIVER___1 OUT OF MERIT. OOM FOR TO LOCAL SECURITY AT START TIME 02/07/2007 04:00 FOR Steam sendout.
07-Feb-2007 05:34:1902/07/2007 05:32:59 NYISO large event reserve pick-up executed.
07-Feb-2007 05:36:33Metering Authority - Consolidated Edison of NY UPDATES EAST_RIVER___2 OUT OF MERIT. OOM FOR TO LOCAL SECURITY AT START TIME 02/07/2007 05:00 FOR Steam sendout.
07-Feb-2007 05:36:50Metering Authority - Consolidated Edison of NY UPDATES EAST_RIVER___1 OUT OF MERIT. OOM FOR TO LOCAL SECURITY AT START TIME 02/07/2007 05:00 FOR Steam sendout.
07-Feb-2007 05:57:51Metering Authority - Consolidated Edison of NY UPDATES EAST_RIVER___2 OUT OF MERIT. OOM FOR TO LOCAL SECURITY AT START TIME 02/07/2007 05:00 FOR Steam sendout.
07-Feb-2007 05:58:10Metering Authority - Consolidated Edison of NY UPDATES EAST_RIVER___1 OUT OF MERIT. OOM FOR TO LOCAL SECURITY AT START TIME 02/07/2007 05:00 FOR Steam sendout.
07-Feb-2007 06:06:25Metering Authority - Consolidated Edison of NY UPDATES EAST_RIVER___2 OUT OF MERIT. OOM FOR TO LOCAL SECURITY AT START TIME 02/07/2007 06:00 FOR Steam sendout.
07-Feb-2007 06:07:37Metering Authority - Consolidated Edison of NY UPDATES EAST_RIVER___1 OUT OF MERIT. OOM FOR TO LOCAL SECURITY AT START TIME 02/07/2007 06:00 FOR Steam sendout.
07-Feb-2007 10:03:34ISO REQUESTS BARRETT___1 OUT OF MERIT. COMMITED FOR ISO RELIABILITY AT START TIME 02/07/2007 10:00 FOR 262 VS-EGC 138KV OVER ACTUAL.
07-Feb-2007 10:36:57ISO REMOVES BARRETT___1 OUT OF MERIT. COMMITED FOR ISO RELIABILITY AT START TIME 02/07/2007 10:00.
07-Feb-2007 11:35:49ISO REQUESTS BARRETT___1 OUT OF MERIT. COMMITED FOR ISO RELIABILITY AT START TIME 02/07/2007 11:00 FOR 262 VS-EGC 138KV OVER POST LTE FOR SCB @ LAKE SUCESS.
07-Feb-2007 12:45:35ISO REMOVES BARRETT___1 OUT OF MERIT. COMMITED FOR ISO RELIABILITY AT START TIME 02/07/2007 12:00.
07-Feb-2007 17:11:46Metering Authority - Consolidated Edison of NY REQUESTS EAST RIVER___6 OUT OF MERIT. OOM FOR TO LOCAL SECURITY AT START TIME 02/07/2007 17:00 FOR STEAM SYSTEM SECURITY.
07-Feb-2007 17:43:4302/07/2007 17:40:11 NYISO large event reserve pick-up executed.
07-Feb-2007 21:02:55Metering Authority - Niagara Mohawk UPDATES CH_RES_NIAGARA OUT OF MERIT. OOM FOR TO LOCAL SECURITY AT START TIME 02/07/2007 21:00 FOR icing on conductors.
07-Feb-2007 21:29:02Metering Authority - Niagara Mohawk REQUESTS CH_RES_NIAGARA OUT OF MERIT. OOM FOR TO LOCAL SECURITY AT START TIME 02/08/2007 00:00 FOR icing on conductors.
07-Feb-2007 21:38:13Metering Authority - Consolidated Edison of NY REQUESTS EAST RIVER___6 OUT OF MERIT. OOM FOR TO LOCAL SECURITY AT START TIME 02/08/2007 00:00 FOR STEAM SYSTEM SECURITY.
07-Feb-2007 21:38:16Metering Authority - Consolidated Edison of NY REQUESTS EAST_RIVER___1 OUT OF MERIT. OOM FOR TO LOCAL SECURITY AT START TIME 02/08/2007 00:00 FOR Steam sendout.
07-Feb-2007 21:38:19Metering Authority - Consolidated Edison of NY REQUESTS EAST_RIVER___2 OUT OF MERIT. OOM FOR TO LOCAL SECURITY AT START TIME 02/08/2007 00:00 FOR Steam sendout.

Committed for Reliability

Back to top
Insert TimeMessage
07-Feb-2007 11:29:55Generator: ARTHUR_KILL_2 scheduled for local reliability in DAM market for 02/08/2007 00 Energy = 90 MW. Regulation = 0 MW. Min10 Spinning = 0 MW. Min10 Nonsynch = 0 MW. Min30 Spinning = 0 MW. Min30 Nonsynch = 0 MW. Operating Cap = 0 MW.
07-Feb-2007 11:29:55Generator: ARTHUR_KILL_2 scheduled for local reliability in DAM market for 02/08/2007 02 Energy = 90 MW. Regulation = 0 MW. Min10 Spinning = 0 MW. Min10 Nonsynch = 0 MW. Min30 Spinning = 0 MW. Min30 Nonsynch = 0 MW. Operating Cap = 0 MW.
07-Feb-2007 11:29:55Generator: ARTHUR_KILL_2 scheduled for local reliability in DAM market for 02/08/2007 01 Energy = 90 MW. Regulation = 0 MW. Min10 Spinning = 0 MW. Min10 Nonsynch = 0 MW. Min30 Spinning = 0 MW. Min30 Nonsynch = 0 MW. Operating Cap = 0 MW.
07-Feb-2007 11:29:55Generator: ARTHUR_KILL_2 scheduled for local reliability in DAM market for 02/08/2007 03 Energy = 90 MW. Regulation = 0 MW. Min10 Spinning = 0 MW. Min10 Nonsynch = 0 MW. Min30 Spinning = 0 MW. Min30 Nonsynch = 0 MW. Operating Cap = 0 MW.
07-Feb-2007 11:29:56Generator: ARTHUR_KILL_2 scheduled for local reliability in DAM market for 02/08/2007 04 Energy = 90 MW. Regulation = 0 MW. Min10 Spinning = 0 MW. Min10 Nonsynch = 0 MW. Min30 Spinning = 0 MW. Min30 Nonsynch = 0 MW. Operating Cap = 0 MW.
07-Feb-2007 11:29:56Generator: ARTHUR_KILL_2 scheduled for local reliability in DAM market for 02/08/2007 05 Energy = 90 MW. Regulation = 0 MW. Min10 Spinning = 0 MW. Min10 Nonsynch = 0 MW. Min30 Spinning = 0 MW. Min30 Nonsynch = 0 MW. Operating Cap = 0 MW.
07-Feb-2007 11:29:56Generator: ARTHUR_KILL_2 scheduled for local reliability in DAM market for 02/08/2007 07 Energy = 90 MW. Regulation = 0 MW. Min10 Spinning = 0 MW. Min10 Nonsynch = 0 MW. Min30 Spinning = 0 MW. Min30 Nonsynch = 0 MW. Operating Cap = 0 MW.
07-Feb-2007 11:29:56Generator: ARTHUR_KILL_2 scheduled for local reliability in DAM market for 02/08/2007 10 Energy = 90 MW. Regulation = 0 MW. Min10 Spinning = 0 MW. Min10 Nonsynch = 0 MW. Min30 Spinning = 0 MW. Min30 Nonsynch = 0 MW. Operating Cap = 0 MW.
07-Feb-2007 11:29:56Generator: ARTHUR_KILL_2 scheduled for local reliability in DAM market for 02/08/2007 09 Energy = 90 MW. Regulation = 0 MW. Min10 Spinning = 0 MW. Min10 Nonsynch = 0 MW. Min30 Spinning = 0 MW. Min30 Nonsynch = 0 MW. Operating Cap = 0 MW.
07-Feb-2007 11:29:56Generator: ARTHUR_KILL_2 scheduled for local reliability in DAM market for 02/08/2007 08 Energy = 90 MW. Regulation = 0 MW. Min10 Spinning = 0 MW. Min10 Nonsynch = 0 MW. Min30 Spinning = 0 MW. Min30 Nonsynch = 0 MW. Operating Cap = 0 MW.
07-Feb-2007 11:29:56Generator: ARTHUR_KILL_2 scheduled for local reliability in DAM market for 02/08/2007 06 Energy = 90 MW. Regulation = 0 MW. Min10 Spinning = 0 MW. Min10 Nonsynch = 0 MW. Min30 Spinning = 0 MW. Min30 Nonsynch = 0 MW. Operating Cap = 0 MW.
07-Feb-2007 11:29:56Generator: ARTHUR_KILL_2 scheduled for local reliability in DAM market for 02/08/2007 11 Energy = 90 MW. Regulation = 0 MW. Min10 Spinning = 0 MW. Min10 Nonsynch = 0 MW. Min30 Spinning = 0 MW. Min30 Nonsynch = 0 MW. Operating Cap = 0 MW.
07-Feb-2007 11:29:56Generator: ARTHUR_KILL_2 scheduled for local reliability in DAM market for 02/08/2007 16 Energy = 90 MW. Regulation = 0 MW. Min10 Spinning = 0 MW. Min10 Nonsynch = 0 MW. Min30 Spinning = 0 MW. Min30 Nonsynch = 0 MW. Operating Cap = 0 MW.
07-Feb-2007 11:29:56Generator: ARTHUR_KILL_2 scheduled for local reliability in DAM market for 02/08/2007 15 Energy = 90 MW. Regulation = 0 MW. Min10 Spinning = 0 MW. Min10 Nonsynch = 0 MW. Min30 Spinning = 0 MW. Min30 Nonsynch = 0 MW. Operating Cap = 0 MW.
07-Feb-2007 11:29:56Generator: ARTHUR_KILL_2 scheduled for local reliability in DAM market for 02/08/2007 14 Energy = 90 MW. Regulation = 0 MW. Min10 Spinning = 0 MW. Min10 Nonsynch = 0 MW. Min30 Spinning = 0 MW. Min30 Nonsynch = 0 MW. Operating Cap = 0 MW.
07-Feb-2007 11:29:56Generator: ARTHUR_KILL_2 scheduled for local reliability in DAM market for 02/08/2007 13 Energy = 90 MW. Regulation = 0 MW. Min10 Spinning = 0 MW. Min10 Nonsynch = 0 MW. Min30 Spinning = 0 MW. Min30 Nonsynch = 0 MW. Operating Cap = 0 MW.
07-Feb-2007 11:29:56Generator: ARTHUR_KILL_2 scheduled for local reliability in DAM market for 02/08/2007 12 Energy = 90 MW. Regulation = 0 MW. Min10 Spinning = 0 MW. Min10 Nonsynch = 0 MW. Min30 Spinning = 0 MW. Min30 Nonsynch = 0 MW. Operating Cap = 0 MW.
07-Feb-2007 11:29:57Generator: ARTHUR_KILL_2 scheduled for local reliability in DAM market for 02/08/2007 17 Energy = 90 MW. Regulation = 0 MW. Min10 Spinning = 0 MW. Min10 Nonsynch = 0 MW. Min30 Spinning = 0 MW. Min30 Nonsynch = 0 MW. Operating Cap = 0 MW.
07-Feb-2007 11:29:57Generator: ARTHUR_KILL_2 scheduled for local reliability in DAM market for 02/08/2007 18 Energy = 90 MW. Regulation = 0 MW. Min10 Spinning = 0 MW. Min10 Nonsynch = 0 MW. Min30 Spinning = 0 MW. Min30 Nonsynch = 0 MW. Operating Cap = 0 MW.
07-Feb-2007 11:29:57Generator: ARTHUR_KILL_2 scheduled for local reliability in DAM market for 02/08/2007 19 Energy = 90 MW. Regulation = 0 MW. Min10 Spinning = 0 MW. Min10 Nonsynch = 0 MW. Min30 Spinning = 0 MW. Min30 Nonsynch = 0 MW. Operating Cap = 0 MW.
07-Feb-2007 11:29:57Generator: ARTHUR_KILL_2 scheduled for local reliability in DAM market for 02/08/2007 23 Energy = 90 MW. Regulation = 0 MW. Min10 Spinning = 0 MW. Min10 Nonsynch = 0 MW. Min30 Spinning = 0 MW. Min30 Nonsynch = 0 MW. Operating Cap = 0 MW.
07-Feb-2007 11:29:57Generator: ARTHUR_KILL_2 scheduled for local reliability in DAM market for 02/08/2007 22 Energy = 90 MW. Regulation = 0 MW. Min10 Spinning = 0 MW. Min10 Nonsynch = 0 MW. Min30 Spinning = 0 MW. Min30 Nonsynch = 0 MW. Operating Cap = 0 MW.
07-Feb-2007 11:29:57Generator: ARTHUR_KILL_2 scheduled for local reliability in DAM market for 02/08/2007 21 Energy = 90 MW. Regulation = 0 MW. Min10 Spinning = 0 MW. Min10 Nonsynch = 0 MW. Min30 Spinning = 0 MW. Min30 Nonsynch = 0 MW. Operating Cap = 0 MW.
07-Feb-2007 11:29:57Generator: ARTHUR_KILL_2 scheduled for local reliability in DAM market for 02/08/2007 20 Energy = 90 MW. Regulation = 0 MW. Min10 Spinning = 0 MW. Min10 Nonsynch = 0 MW. Min30 Spinning = 0 MW. Min30 Nonsynch = 0 MW. Operating Cap = 0 MW.
07-Feb-2007 11:30:28Generator: RAVENSWOOD___1 scheduled for local reliability in DAM market for 02/08/2007 22 Energy = 75 MW. Regulation = 0 MW. Min10 Spinning = 0 MW. Min10 Nonsynch = 0 MW. Min30 Spinning = 0 MW. Min30 Nonsynch = 0 MW. Operating Cap = 0 MW.
07-Feb-2007 11:30:28Generator: RAVENSWOOD___1 scheduled for local reliability in DAM market for 02/08/2007 23 Energy = 75 MW. Regulation = 0 MW. Min10 Spinning = 0 MW. Min10 Nonsynch = 0 MW. Min30 Spinning = 0 MW. Min30 Nonsynch = 0 MW. Operating Cap = 0 MW.
07-Feb-2007 11:30:57Generator: RAVENSWOOD___3 scheduled for local reliability in DAM market for 02/08/2007 22 Energy = 150 MW. Regulation = 0 MW. Min10 Spinning = 0 MW. Min10 Nonsynch = 0 MW. Min30 Spinning = 0 MW. Min30 Nonsynch = 0 MW. Operating Cap = 0 MW.
07-Feb-2007 11:30:57Generator: RAVENSWOOD___3 scheduled for local reliability in DAM market for 02/08/2007 23 Energy = 150 MW. Regulation = 0 MW. Min10 Spinning = 0 MW. Min10 Nonsynch = 0 MW. Min30 Spinning = 0 MW. Min30 Nonsynch = 0 MW. Operating Cap = 0 MW.
07-Feb-2007 13:59:56Generator: ASTORIA___4 scheduled for local reliability in DAM market for 02/08/2007 00 Energy = 75 MW. Regulation = 0 MW. Min10 Spinning = 0 MW. Min10 Nonsynch = 0 MW. Min30 Spinning = 0 MW. Min30 Nonsynch = 0 MW. Operating Cap = 0 MW.
07-Feb-2007 13:59:56Generator: ASTORIA___4 scheduled for local reliability in DAM market for 02/08/2007 01 Energy = 75 MW. Regulation = 0 MW. Min10 Spinning = 0 MW. Min10 Nonsynch = 0 MW. Min30 Spinning = 0 MW. Min30 Nonsynch = 0 MW. Operating Cap = 0 MW.
07-Feb-2007 13:59:57Generator: ASTORIA___4 scheduled for local reliability in DAM market for 02/08/2007 02 Energy = 75 MW. Regulation = 0 MW. Min10 Spinning = 0 MW. Min10 Nonsynch = 0 MW. Min30 Spinning = 0 MW. Min30 Nonsynch = 0 MW. Operating Cap = 0 MW.
07-Feb-2007 13:59:57Generator: ASTORIA___4 scheduled for local reliability in DAM market for 02/08/2007 09 Energy = 75 MW. Regulation = 0 MW. Min10 Spinning = 0 MW. Min10 Nonsynch = 0 MW. Min30 Spinning = 0 MW. Min30 Nonsynch = 0 MW. Operating Cap = 0 MW.
07-Feb-2007 13:59:57Generator: ASTORIA___4 scheduled for local reliability in DAM market for 02/08/2007 12 Energy = 75 MW. Regulation = 0 MW. Min10 Spinning = 0 MW. Min10 Nonsynch = 0 MW. Min30 Spinning = 0 MW. Min30 Nonsynch = 0 MW. Operating Cap = 0 MW.
07-Feb-2007 13:59:57Generator: ASTORIA___4 scheduled for local reliability in DAM market for 02/08/2007 11 Energy = 75 MW. Regulation = 0 MW. Min10 Spinning = 0 MW. Min10 Nonsynch = 0 MW. Min30 Spinning = 0 MW. Min30 Nonsynch = 0 MW. Operating Cap = 0 MW.
07-Feb-2007 13:59:57Generator: ASTORIA___4 scheduled for local reliability in DAM market for 02/08/2007 10 Energy = 75 MW. Regulation = 0 MW. Min10 Spinning = 0 MW. Min10 Nonsynch = 0 MW. Min30 Spinning = 0 MW. Min30 Nonsynch = 0 MW. Operating Cap = 0 MW.
07-Feb-2007 13:59:57Generator: ASTORIA___4 scheduled for local reliability in DAM market for 02/08/2007 08 Energy = 75 MW. Regulation = 0 MW. Min10 Spinning = 0 MW. Min10 Nonsynch = 0 MW. Min30 Spinning = 0 MW. Min30 Nonsynch = 0 MW. Operating Cap = 0 MW.
07-Feb-2007 13:59:57Generator: ASTORIA___4 scheduled for local reliability in DAM market for 02/08/2007 03 Energy = 75 MW. Regulation = 0 MW. Min10 Spinning = 0 MW. Min10 Nonsynch = 0 MW. Min30 Spinning = 0 MW. Min30 Nonsynch = 0 MW. Operating Cap = 0 MW.
07-Feb-2007 13:59:57Generator: ASTORIA___4 scheduled for local reliability in DAM market for 02/08/2007 05 Energy = 75 MW. Regulation = 0 MW. Min10 Spinning = 0 MW. Min10 Nonsynch = 0 MW. Min30 Spinning = 0 MW. Min30 Nonsynch = 0 MW. Operating Cap = 0 MW.
07-Feb-2007 13:59:57Generator: ASTORIA___4 scheduled for local reliability in DAM market for 02/08/2007 06 Energy = 75 MW. Regulation = 0 MW. Min10 Spinning = 0 MW. Min10 Nonsynch = 0 MW. Min30 Spinning = 0 MW. Min30 Nonsynch = 0 MW. Operating Cap = 0 MW.
07-Feb-2007 13:59:57Generator: ASTORIA___4 scheduled for local reliability in DAM market for 02/08/2007 07 Energy = 75 MW. Regulation = 0 MW. Min10 Spinning = 0 MW. Min10 Nonsynch = 0 MW. Min30 Spinning = 0 MW. Min30 Nonsynch = 0 MW. Operating Cap = 0 MW.
07-Feb-2007 13:59:57Generator: ASTORIA___4 scheduled for local reliability in DAM market for 02/08/2007 04 Energy = 75 MW. Regulation = 0 MW. Min10 Spinning = 0 MW. Min10 Nonsynch = 0 MW. Min30 Spinning = 0 MW. Min30 Nonsynch = 0 MW. Operating Cap = 0 MW.
07-Feb-2007 13:59:58Generator: ASTORIA___4 scheduled for local reliability in DAM market for 02/08/2007 13 Energy = 75 MW. Regulation = 0 MW. Min10 Spinning = 0 MW. Min10 Nonsynch = 0 MW. Min30 Spinning = 0 MW. Min30 Nonsynch = 0 MW. Operating Cap = 0 MW.
07-Feb-2007 13:59:58Generator: ASTORIA___4 scheduled for local reliability in DAM market for 02/08/2007 15 Energy = 75 MW. Regulation = 0 MW. Min10 Spinning = 0 MW. Min10 Nonsynch = 0 MW. Min30 Spinning = 0 MW. Min30 Nonsynch = 0 MW. Operating Cap = 0 MW.
07-Feb-2007 13:59:58Generator: ASTORIA___4 scheduled for local reliability in DAM market for 02/08/2007 17 Energy = 75 MW. Regulation = 0 MW. Min10 Spinning = 0 MW. Min10 Nonsynch = 0 MW. Min30 Spinning = 0 MW. Min30 Nonsynch = 0 MW. Operating Cap = 0 MW.
07-Feb-2007 13:59:58Generator: ASTORIA___4 scheduled for local reliability in DAM market for 02/08/2007 19 Energy = 75 MW. Regulation = 0 MW. Min10 Spinning = 0 MW. Min10 Nonsynch = 0 MW. Min30 Spinning = 0 MW. Min30 Nonsynch = 0 MW. Operating Cap = 0 MW.
07-Feb-2007 13:59:58Generator: ASTORIA___4 scheduled for local reliability in DAM market for 02/08/2007 21 Energy = 75 MW. Regulation = 0 MW. Min10 Spinning = 0 MW. Min10 Nonsynch = 0 MW. Min30 Spinning = 0 MW. Min30 Nonsynch = 0 MW. Operating Cap = 0 MW.
07-Feb-2007 13:59:58Generator: ASTORIA___4 scheduled for local reliability in DAM market for 02/08/2007 23 Energy = 75 MW. Regulation = 0 MW. Min10 Spinning = 0 MW. Min10 Nonsynch = 0 MW. Min30 Spinning = 0 MW. Min30 Nonsynch = 0 MW. Operating Cap = 0 MW.
07-Feb-2007 13:59:58Generator: ASTORIA___4 scheduled for local reliability in DAM market for 02/08/2007 22 Energy = 75 MW. Regulation = 0 MW. Min10 Spinning = 0 MW. Min10 Nonsynch = 0 MW. Min30 Spinning = 0 MW. Min30 Nonsynch = 0 MW. Operating Cap = 0 MW.
07-Feb-2007 13:59:58Generator: ASTORIA___4 scheduled for local reliability in DAM market for 02/08/2007 20 Energy = 75 MW. Regulation = 0 MW. Min10 Spinning = 0 MW. Min10 Nonsynch = 0 MW. Min30 Spinning = 0 MW. Min30 Nonsynch = 0 MW. Operating Cap = 0 MW.
07-Feb-2007 13:59:58Generator: ASTORIA___4 scheduled for local reliability in DAM market for 02/08/2007 18 Energy = 75 MW. Regulation = 0 MW. Min10 Spinning = 0 MW. Min10 Nonsynch = 0 MW. Min30 Spinning = 0 MW. Min30 Nonsynch = 0 MW. Operating Cap = 0 MW.
07-Feb-2007 13:59:58Generator: ASTORIA___4 scheduled for local reliability in DAM market for 02/08/2007 16 Energy = 75 MW. Regulation = 0 MW. Min10 Spinning = 0 MW. Min10 Nonsynch = 0 MW. Min30 Spinning = 0 MW. Min30 Nonsynch = 0 MW. Operating Cap = 0 MW.
07-Feb-2007 13:59:58Generator: ASTORIA___4 scheduled for local reliability in DAM market for 02/08/2007 14 Energy = 75 MW. Regulation = 0 MW. Min10 Spinning = 0 MW. Min10 Nonsynch = 0 MW. Min30 Spinning = 0 MW. Min30 Nonsynch = 0 MW. Operating Cap = 0 MW.

Market Monitor Notices

Back to top
Insert TimeMessage
07-Feb-2007 16:32:22Prices in the 06 February 2007 Real-Time Market for the period hours beginning 12 through 23 encompassing Energy, Regulation, and Operating Reserves are correct. Prices in the 06 February 2007 Hour-Ahead Market for the period hours beginning 12 through 23 are correct. Prices in the 08 February 2007 Day-Ahead Market are correct.
07-Feb-2007 16:34:51Prices in the 07 February 2007 Real-Time Market for hours beginning 00 through 11 encompassing Energy, Regulation, and Operating Reserves are correct. Prices in the 07 February 2007 Hour-Ahead Market for hours beginning 00 through 11 are correct.